1.
J Arthroplasty ; 16(8): 1081-3, 2001 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11740769

RESUMO

The removal of well-fixed, porous-coated acetabular components at the time of revision total hip arthroplasty can be challenging. The presence of spike fixation can increase the difficulty of removing an acetabular component because traditional methods of component removal, such as the use of curved gouges, may not be possible. We report a novel technique for the removal of well-fixed, porous-coated acetabular components with adjunctive spike fixation. This technique uses an overlay template that targets the spikes for removal with a high-speed, carbide-tipped bur.


Assuntos
Artroplastia de Quadril , Remoção de Dispositivo/métodos , Prótese de Quadril , Acetábulo , Materiais Revestidos Biocompatíveis , Humanos , Falha de Prótese , Reoperação
2.
J Arthroplasty ; 16(6): 759-67, 2001 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-11547375

RESUMO

The effect of stem length, diameter, and mode of fixation on the motion and stress transfer of a cemented tibial tray were evaluated for in 12 cadaver knees. There was a significant decrease in motion of the tibial tray with increasing press-fit stem length (75-150 mm) and increasing stem diameter (10-14 mm). Cemented tibial stems showed significantly less tray motion than uncemented stems. The short cemented stems produced tray stability equivalent to long press-fit stems. Although there was a trend for increased proximal tibial stress shielding with the use of cement and longer, wider stems, the trend was not statistically significant. Modular, press-fit stems can achieve tray stability similar to a smaller cemented stem and can avoid the potential problems with cement.


Assuntos
Análise de Falha de Equipamento , Prótese do Joelho , Amplitude de Movimento Articular/fisiologia , Suporte de Carga/fisiologia , Adulto , Fenômenos Biomecânicos , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/fisiopatologia , Complicações Pós-Operatórias/cirurgia , Desenho de Prótese , Reoperação
3.
J Hand Surg Br ; 26(3): 258-60, 2001 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-11386780

RESUMO

This retrospective study compares two methods used to treat de Quervain's disease: splintage with oral non-steroidal anti-inflammatory drugs (NSAIDs) and steroid injection. Patients were separated into three groups based on symptom severity: group I-minimal, group II-mild, and group III-moderate or severe. Three hundred and nineteen wrists in 300 patients were followed from one to six years. Fifteen of 17 patients with minimal symptoms were relieved with splintage and NSAIDs. However, only seven of 20 in Group II and two of eight in Group III treated similarly were relieved. Of the 249 patients in Group III treated with injections, 76% were completely relieved, 7% were improved, and 4% were not improved. We conclude that classification of patients' with de Quervain's disease based on their pre-treatment symptoms may assist surgeons in selecting the most efficacious treatment and in providing prognostic information to their patients.


Assuntos
Betametasona/análogos & derivados , Betametasona/administração & dosagem , Naproxeno/administração & dosagem , Contenções , Tenossinovite/reabilitação , Administração Oral , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Terapia Combinada , Feminino , Seguimentos , Humanos , Injeções Intra-Articulares , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tenossinovite/classificação
5.
J Arthroplasty ; 15(2): 187-93, 2000 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-10708084

RESUMO

Clinical and radiographic results of 116 patients who had undergone 132 hip arthroplasties at our institution from 1983 to 1988 with a collared cemented straight cobalt-chrome femoral stem using second-generation cementing technique were reviewed. Twenty hips in 20 patients who were part of the original cohort were lost to follow-up. Mean age at the time of surgery was 68.2 years. Mean radiographic follow-up was 9.6 years with a minimum follow-up of 5 years. Ten-year survivorship of the component was 96.5% with revision considered as an endpoint and 94.2% with either revision or radiographic loosening considered the endpoint. Three implants (2.3%) were revised for aseptic loosening at a mean of 8.1 years after implantation. One implant (0.8%) was revised for septic loosening at 10.5 years after surgery. Of the implants not revised, 1 showed evidence of circumferential bone-cement radiolucencies, and 1 had radiolucencies at the implant-cement interface. Five of the surviving femoral components (5.0%) showed focal areas of cystic osteolysis, and proximal femoral bone resorption under the collar was seen in 32 patients (31.7%). There were no cases of cement fracture or stem subsidence. The biomechanical and material properties of this stem combined with second-generation cementing technique look promising for long-term survivorship.


Assuntos
Artroplastia de Quadril/métodos , Cimentos Ósseos , Prótese de Quadril , Idoso , Cimentação , Ligas de Cromo , Estudos de Coortes , Feminino , Seguimentos , Articulação do Quadril/diagnóstico por imagem , Prótese de Quadril/estatística & dados numéricos , Humanos , Masculino , Desenho de Prótese , Falha de Prótese , Radiografia , Fatores de Tempo
6.
J Bone Joint Surg Am ; 82(2): 207-12, 2000 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-10682729

RESUMO

BACKGROUND: Treatment of thromboembolism with intravenous heparin therapy in the early postoperative period after total joint arthroplasty has been associated with a high rate of complications. The purpose of the present study was to compare the rate of bleeding complications in a group of patients who required intravenous heparin therapy for the treatment of thromboembolism after total hip or knee arthroplasty with the rate in a control group of patients who received only prophylactic anticoagulation. METHODS: The postoperative courses of forty-four consecutive patients who were managed with intravenous administration of heparin and oral administration of warfarin for the treatment of a thromboembolic event following unilateral total hip or knee arthroplasty were compared with those of a control group of 376 consecutive patients who had these same procedures but did not have a thromboembolic complication. The patients in the control group were managed with prophylactic anticoagulation with use of enoxaparin. Sixty-eight percent (thirty) of the forty-four patients in the heparin group received the initial dose of heparin on or before the fourth postoperative day, and 82 percent (thirty-six) received an initial bolus of 5000 units of heparin at the initiation of therapy. RESULTS: The rate of bleeding complications was 9 percent (four of forty-four) in the heparin group, compared with 6 percent (twenty-three of 376) in the control group (p = 0.44). The mean transfusion requirement in the heparin group (1.8 units of packed red blood cells) was significantly greater than that in the control group (0.8 unit) (p < 0.0001). Three of the four patients who had a bleeding complication while receiving heparin and warfarin had coagulation parameters that were substantially higher than recommended levels. The mean duration of hospitalization in the heparin group (fifteen days) was significantly longer than that in the control group (seven days) (p < 0.0001). CONCLUSIONS: The results of the present study suggest that the use of intravenous heparin therapy for the treatment of thromboembolism in the early postoperative period after total joint arthroplasty is associated with a rate of bleeding complications that is similar to that associated with the use of prophylactic anticoagulation with use of enoxaparin alone. One should expect an increased transfusion requirement and a longer duration of hospitalization for patients who require intravenous heparin therapy for the treatment of a thromboembolic event.


Assuntos
Anticoagulantes/administração & dosagem , Artroplastia de Quadril , Artroplastia do Joelho , Heparina/administração & dosagem , Cuidados Pós-Operatórios/métodos , Complicações Pós-Operatórias/tratamento farmacológico , Tromboembolia/tratamento farmacológico , Adulto , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/efeitos adversos , Feminino , Hemorragia/sangue , Hemorragia/induzido quimicamente , Heparina/efeitos adversos , Humanos , Infusões Intravenosas , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/sangue , Prognóstico , Estudos Retrospectivos , Tromboembolia/sangue , Fatores de Tempo
7.
J Arthroplasty ; 14(7): 781-7, 1999 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-10537250

RESUMO

A retrospective clinical and radiographic analysis was performed on 58 patients (60 hips; mean age at time of surgery, 45.2 years) at a minimum of 10-year follow-up (mean, 12.7 years) after total hip replacement using a ceramic-on-ceramic hearing total hip implant (Autophor, Smith and Nephew, Memphis, TN). Mean wear rate at final follow-up was 0.21 mim, averaging 0.016 mm/y. There were no cases of periprosthetic osteolysis in the acetabuulum or femur. For the unrevised components, there were 3 (5%) cases of protrusio acetabuli and 4 (7%) cases of acetabular component loosening. On the femoral side, 78.3% had distal pedestal formation, and 83% had greater than 2 mm implant-bone radiolucencies in more than 5 Gruen zones as a result of gross motion of the stem. Despite radiographic evidence of implant loosening, this hard bearing articulation functioned well in vivo for more than 12 years with remarkably low wear--approximately one tenth the rate reported for metal-on-polyethylene total hip bearings.


Assuntos
Cerâmica , Prótese de Quadril , Adulto , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Estudos Retrospectivos
8.
J Immunol ; 163(6): 3459-67, 1999 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-10477618

RESUMO

Tetracyclines (doxycycline and minocycline) inhibit inducible NO synthase expression and augment cyclooxygenase (COX)-2 expression and PGE2 production. In contrast, chemically modified tetracyclines (CMTs), such as CMT-3 and -8 (but not CMT-1, -2, and -5), that lack antimicrobial activity, inhibit both NO and PGE2 production in LPS-stimulated murine macrophages, bovine chondrocytes, and human osteoarthritis-affected cartilage, which spontaneously produces NO and PGE2 in ex vivo conditions. Furthermore, CMT-3 augments COX-2 protein expression but inhibits net PGE2 accumulation. This coincides with the ability of CMT-3 and -8 to inhibit COX-2 enzyme activity in vitro. The action of CMTs is distinct from that observed with tetracyclines because 1) CMT-3-mediated inhibition of PGE2 production coincides with modification of COX-2 protein, which is distinct from the nonglycosylated COX-2 protein generated in the presence of tunicamycin, as observed by Western blot analysis and 2) CMT-3 and -8 have no significant effect on COX-2 mRNA accumulation. In contrast, CMT-3 and -8 do not inhibit COX-1 expression in A549 human epithelial cells at the level of protein and mRNA accumulation or modification of COX-1 protein. CMT-3 and -8 inhibit the sp. act. of COX-2 (but not COX-1) in cell-free extracts. These results demonstrate differential action of CMT-3 (Metastat) on COX-1 and -2 expression, which is distinct from other tetracyclines.


Assuntos
Inibidores de Ciclo-Oxigenase/farmacologia , Dinoprostona/antagonistas & inibidores , Dinoprostona/biossíntese , Isoenzimas/fisiologia , Prostaglandina-Endoperóxido Sintases/fisiologia , Tetraciclinas/farmacologia , Animais , Western Blotting , Bovinos , Linhagem Celular , Ciclo-Oxigenase 2 , Inibidores de Ciclo-Oxigenase 2 , Inibidores de Ciclo-Oxigenase/química , Dinoprostona/metabolismo , Ativação Enzimática/efeitos dos fármacos , Células Epiteliais/efeitos dos fármacos , Células Epiteliais/enzimologia , Células Epiteliais/metabolismo , Glicosilação/efeitos dos fármacos , Humanos , Isoenzimas/biossíntese , Isoenzimas/isolamento & purificação , Isoenzimas/metabolismo , Proteínas de Membrana , Camundongos , Óxido Nítrico/metabolismo , Óxido Nítrico/fisiologia , Técnicas de Cultura de Órgãos , Prostaglandina-Endoperóxido Sintases/biossíntese , Prostaglandina-Endoperóxido Sintases/isolamento & purificação , Prostaglandina-Endoperóxido Sintases/metabolismo , RNA Mensageiro/biossíntese , RNA Mensageiro/efeitos dos fármacos , Tetraciclinas/química , Células Tumorais Cultivadas , Tunicamicina/farmacologia
10.
J Immunol ; 160(9): 4570-9, 1998 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-9574564

RESUMO

A snake venom-like protease isolated by a differential display screen between normal and osteoarthritis (OA)-affected cartilage (designated as cSVP) has a cDNA sequence identical to TNF-alpha convertase enzyme (TACE). TACE shows the presence of an unknown prodomain, a cysteine switch, a catalytic domain, a zinc binding region, a disintegrin region, an EGF-like domain, a transmembrane domain, and a unique cytoplasmic region. A TACE construct harboring the signal + prodomain + catalytic region (TACE-SPCdeltaDETCy), expressed in baculovirus could cleave preferentially (approximately 12-fold) the TNF-specific peptide over the matrix metalloproteases peptide in vitro. This recombinant protein also cleaved the natural substrate GST-ProTNF-alpha to TNF-alpha (17 kDa) in vitro. The mRNA for TACE, which is broadly distributed and differentially expressed in a variety of human tissues, is up-regulated in arthritis-affected cartilage, but not normal cartilage. OA-affected cartilage also expressed TNF-alpha mRNA that was not detected in normal cartilage. The OA-affected cartilage (in explant assays) spontaneously released TNF-alpha and IL-8 in ex vivo conditions. Addition of TNF-alphaR fused to IgG Fc fragment (TNF-alphaR:Fc) in the presence or absence of soluble IL-1R (with which it acted additively) significantly attenuated the spontaneous/autocrine release of articular IL-8 in this assay. These experiments demonstrate a functional paracrine/autocrine role of TNF-alpha in OA-affected cartilage that may depend, in part, on up-regulated levels of chondrocyte-derived TACE.


Assuntos
Artrite Reumatoide/genética , Cartilagem/enzimologia , DNA Complementar/genética , Regulação Enzimológica da Expressão Gênica/efeitos dos fármacos , Metaloendopeptidases/genética , Fator de Necrose Tumoral alfa/farmacologia , Proteínas ADAM , Proteína ADAM17 , Artrite Reumatoide/enzimologia , Clonagem Molecular , DNA Complementar/isolamento & purificação , Humanos , Metaloendopeptidases/biossíntese , Dados de Sequência Molecular , Técnicas de Cultura de Órgãos , Análise de Sequência
11.
J Arthroplasty ; 13(1): 108-13, 1998 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-9493548

RESUMO

Recent research in total hip arthroplasty has focused on attempts to decrease wear at the femoral head-acetabulum articulation, to limit the production of debris that is believed to lead to osteolysis and prosthetic loosening. The use of ceramic-on-polyethylene bearing surfaces has been reported to produce lower wear rates and therefore may increase the life expectancy of the joint arthroplasty. Problems with this bearing have been reported to be due to ceramic femoral head fracture. Reported here are 2 cases of catastrophic failure of total hip arthroplasties, involving a ceramic femoral head, caused by failure of the polyethylene acetabular liner, with subsequent penetration of the femoral head through the acetabular shell.


Assuntos
Acetábulo , Artroplastia de Quadril/efeitos adversos , Cerâmica , Polietilenos , Falha de Prótese , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Adulto , Colo do Fêmur/diagnóstico por imagem , Colo do Fêmur/cirurgia , Prótese de Quadril , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia , Reoperação , Estudos Retrospectivos
12.
J Arthroplasty ; 13(8): 867-73, 1998 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-9880177

RESUMO

The clinical and radiographic results of 86 primary total hip arthroplasties performed in 74 patients from 1983 to 1987 with a cemented metal-backed acetabular component and a cemented collared straight femoral stem with a 32-mm head were reviewed at a mean follow-up of 10.1 years. Seven patients (9.2%) underwent acetabular component revision at a mean of 9.0 years after implantation; an additional 24 components (31.6%) demonstrated evidence of radiographic loosening, resulting in a total failure rate of 40.8%. Periacetabular radiolucencies were noted in Charnley zones at the following rates: 34.2% in zone I, 18.4% in zone II, and 27.6% in zone III. In addition, 18.4% and 38.2% of implants demonstrated evidence of migration and excessive polyethylene wear. Excessively vertical cup placement (>49 degrees inclination) at the time of initial arthroplasty was statistically correlated with polyethylene wear, implant migration, and fixation failure. A trend of increasing implant failure was also noted with decreasing polyethylene liner thickness. Periacetabular cement mantle thickness was not statistically correlated with subsequent component loosening or failure. Results of Kaplan-Meier survivorship analysis using revision as an endpoint showed 93.6% survivorship at 10 years and 88.4% at 12 years. The mean modified Harris hip scores were 46.9 preoperatively and 81.8 at final follow-up. The significant overall rates of radiographic loosening, migration, polyethylene wear, and implant revision confirm the suspected trend of increasing failure rates of cemented metal-backed acetabular components over time.


Assuntos
Artroplastia de Quadril/métodos , Cimentos Ósseos , Prótese de Quadril , Acetábulo , Idoso , Artroplastia de Quadril/estatística & dados numéricos , Feminino , Seguimentos , Articulação do Quadril/diagnóstico por imagem , Humanos , Masculino , Polietilenos , Desenho de Prótese , Falha de Prótese , Radiografia , Reoperação/estatística & dados numéricos , Fatores de Tempo
13.
J Clin Invest ; 99(6): 1231-7, 1997 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-9077531

RESUMO

Cartilage specimens from osteoarthritis (OA)-affected patients spontaneously released PGE2 at 48 h in ex vivo culture at levels at least 50-fold higher than in normal cartilage and 18-fold higher than in normal cartilage + cytokines + endotoxin. The superinduction of PGE2 production coincides with the upregulation of cyclooxygenase-2 (COX-2) in OA-affected cartilage. Production of both nitric oxide (NO) and PGE2 by OA cartilage explants is regulated at the level of transcription and translation. Dexamethasone inhibited only the spontaneously released PGE2 production, and not NO, in OA-affected cartilage. The NO synthase inhibitor HN(G)-monomethyl-L-arginine monoacetate inhibited OA cartilage NO production by > 90%, but augmented significantly (twofold) the spontaneous production of PGE2 in the same explants. Similarly, addition of exogenous NO donors to OA cartilage significantly inhibited PGE2 production. Cytokine + endotoxin stimulation of OA explants increased PGE2 production above the spontaneous release. Addition of L-NMMA further augmented cytokine-induced PGE2 production by at least fourfold. Inhibition of PGE2 by COX-2 inhibitors (dexamethasone or indomethacin) or addition of exogenous PGE2 did not significantly affect the spontaneous NO production. These data indicate that human OA-affected cartilage in ex vivo conditions shows (a) superinduction of PGE2 due to upregulation of COX-2, and (b) spontaneous release of NO that acts as an autacoid to attenuate the production of the COX-2 products such as PGE2. These studies, together with others, also suggest that PGE2 may be differentially regulated in normal and OA-affected chondrocytes.


Assuntos
Cartilagem Articular/enzimologia , Isoenzimas/biossíntese , Óxido Nítrico/fisiologia , Osteoartrite/enzimologia , Prostaglandina-Endoperóxido Sintases/biossíntese , Adulto , Idoso , Sequência de Bases , Ciclo-Oxigenase 2 , Dinoprostona/antagonistas & inibidores , Dinoprostona/biossíntese , Dinoprostona/metabolismo , Indução Enzimática/efeitos dos fármacos , Humanos , Isoenzimas/genética , Proteínas de Membrana , Pessoa de Meia-Idade , Dados de Sequência Molecular , Óxido Nítrico/metabolismo , Prostaglandina-Endoperóxido Sintases/genética , RNA Mensageiro/biossíntese
14.
J Hand Surg Am ; 22(2): 279-85, 1997 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-9195427

RESUMO

A retrospective study was performed to analyze the results of elbow synovectomy, radial head excision, and anterior capsular release in 12 elbows in 11 patients with radiographic stage III inflammatory arthritis. The follow-up period averaged 6.1 years. Average flexion arc improved from 93 degrees (range, 80 degrees-110 degrees) to 116 degrees (range, 65 degrees-140 degrees), with flexion contracture improving 13 degrees. Total arc of forearm rotation increased from 95 degrees to 145 degrees. Ewald scores improved from an average of 37 to 84 points. Pain was eliminated or improved in all cases; functional improvement was noted in all patients. Serial postoperative radiographs showed no significant disease progression over time. These results suggest that combined synovectomy, radial head excision, and anterior capsular release effectively relieves pain and improves function in stage III inflammatory arthritis of the elbow.


Assuntos
Artrite Reumatoide/cirurgia , Articulação do Cotovelo/cirurgia , Cápsula Articular/cirurgia , Rádio (Anatomia)/cirurgia , Sinovectomia , Adulto , Idoso , Artrite Juvenil/fisiopatologia , Artrite Juvenil/cirurgia , Artrite Psoriásica/fisiopatologia , Artrite Psoriásica/cirurgia , Artrite Reumatoide/classificação , Artrite Reumatoide/diagnóstico por imagem , Artrite Reumatoide/fisiopatologia , Progressão da Doença , Feminino , Seguimentos , Antebraço/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Contração Muscular , Dor/cirurgia , Radiografia , Amplitude de Movimento Articular , Estudos Retrospectivos , Rotação , Resultado do Tratamento
15.
J Arthroplasty ; 12(8): 880-8, 1997 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-9458253

RESUMO

A surgical technique, which uses a transverse osteotomy, for subtrochanteric femoral shortening and derotation in total hip arthroplasty for high-riding developmental dislocation of the hip is described. Anteversion is set by rotating the osteotomy fragments, and torsional stability is augmented with allograft struts and cables when indicated. Eight patients with 9 total hip arthroplasties were followed for an average of 43 months (range, 24-84 months). Good to excellent results were obtained in 87% of patients (7 of 8). Eight of 9 osteotomies (89%) demonstrated radiographic evidence of healing at an average of 5 months. One patient had an asymptomatic nonunion of the osteotomy site but still had a good overall clinical result. Another patient suffered fatigue failure of a distally ingrown porous device, which necessitated revision total hip arthroplasty 18 months after surgery. Subtrochanteric osteotomy in total hip arthroplasty for developmental dislocation of the hip allows for acetabular exposure and diaphyseal shortening while facilitating femoral derotation. Furthermore, proximal femoral bone stock is maintained and some of the potential complications of greater trochanteric osteotomy may be avoided.


Assuntos
Artroplastia de Quadril , Fêmur/cirurgia , Luxação do Quadril/cirurgia , Osteotomia/métodos , Adulto , Idoso , Placas Ósseas , Parafusos Ósseos , Transplante Ósseo/métodos , Feminino , Seguimentos , Luxação do Quadril/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia , Estudos Retrospectivos , Transplante Homólogo , Resultado do Tratamento
16.
Clin Orthop Relat Res ; (331): 102-6, 1996 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-8895625

RESUMO

A synthetic femur and tibia were used to create a model resurfacing total knee arthroplasty. The femoral component was placed in 7 degrees valgus; the tibial component was placed in 2 degrees varus with a 5 degrees posterior slope. The overall anatomic alignment was 5 degrees valgus. A series of radiographs were taken on 14 inch x 17 inch plates, in full extension and 10 degrees flexion, with the limb rotated, in 5 degree increments, from 20 degrees external rotation to 25 degrees internal rotation. Seven orthopaedic surgeons independently measured the tibiofemoral angle and tibial alignment for each series of radiographs; interobserver variability was insignificant. Average radiographic anatomic alignment ranged from 2.29 degrees valgus in 20 degrees external rotation and 10 degrees flexion, to 6.73 degrees valgus in 25 degrees internal rotation and 10 degrees flexion. Limb rotation and knee flexion of 10 degrees, either alone or in combination, had a highly statistically significant effect on measured values of the anatomic alignment. Tibial alignment ranged from 5 degrees varus in 20 degrees external rotation to 3 degrees valgus in 25 degrees internal rotation, with the knee flexed 10 degrees. The variability associated with changes in rotation was statistically significant. Changes associated with rotation, when the knee was flexed 10 degrees, were not significantly different than those measured with the knee fully extended. Even in a well aligned total knee arthroplasty, limb positioning at the time of radiographic assessment will alter the apparent alignment indices, making objective evaluation difficult.


Assuntos
Articulação do Joelho/diagnóstico por imagem , Prótese do Joelho/métodos , Amplitude de Movimento Articular , Humanos , Articulação do Joelho/anatomia & histologia , Articulação do Joelho/fisiologia , Modelos Anatômicos , Radiografia , Rotação
17.
J Arthroplasty ; 11(4): 438-44, 1996 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-8792251

RESUMO

The sciatic nerve in 52 hip arthroplasties was evaluated using intraoperative somatosensory evoked potentials (SSEPs). Twenty-nine of these cases involved the lateral transtrochanteric approach, and 23 involved the posterior approach. A total of 11 incidents of SSEP changes occurred in eight patients. Six episodes occurred during lateral retraction of the proximal femur, and three occurred during anterior retraction of the proximal femur. Tracings returned to baseline with prompt cessation of femoral retraction in each case. One SSEP change occurred in a revision following reduction of the prosthetic components, and this resolved with shortening of the prosthetic neck to less than anatomic length. One change occurred during tightening of cables securing strut allografts to the femur and this resolved spontaneously. No correlation was found between frequency of SSEP changes and age, sex, limb lengthening, or preoperative range of motion. It is concluded that routine lateral or anterior retraction may place the sciatic nerve at risk.


Assuntos
Potenciais Somatossensoriais Evocados/fisiologia , Articulação do Quadril/inervação , Prótese de Quadril/efeitos adversos , Complicações Intraoperatórias/fisiopatologia , Nervo Isquiático/fisiopatologia , Feminino , Articulação do Quadril/cirurgia , Humanos , Complicações Intraoperatórias/etiologia , Complicações Intraoperatórias/prevenção & controle , Masculino , Monitorização Intraoperatória , Fatores de Risco , Nervo Isquiático/lesões
18.
J Exp Med ; 182(6): 2097-102, 1995 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-7500055

RESUMO

Classically, osteoarthritis (OA) has been considered a noninflammatory disease. However, the detection of selected inflammatory mediators in osteoarthritic fluid, in the absence of significant inflammatory cell infiltrate, is increasingly appreciated. We sought to identify the inflammatory component in human OA-affected cartilage that may be involved in cartilage damage/destruction. Using Western blot analysis and an antibody to the conserved region of nitric oxide synthase (NOS), we have observed up-regulation of NOS, one of the "key players" of inflammation, in chondrocytes of OA-affected patients. Remarkably, none of the cartilage samples examined from normal joints demonstrated detectable amounts of this NOS. Western blot analysis using the same alpha-NOS antibody indicated that this NOS from OA-affected cartilage (OA-NOS) was larger in size than (and distinct from) transfected human hepatocyte or murine inducible NOS (iNOS) (150 versus 133 kD) and similar in size to neuronal constitutive NOS (ncNOS). Antibodies specific for iNOS showed binding to murine and human iNOS but not to OA-NOS, endothelial constitutive NOS, or ncNOS. Antibodies specific for ncNOS bound to ncNOS and also to OA-NOS, but not to murine or human iNOS or endothelial constitutive NOS. Incubation of OA cartilage in serum-free medium resulted in spontaneous release, for up to 72 h, of substantial amounts of nitrite (up to approximately 80 microM/100 mg wet tissue), which could be inhibited by at least 80% with various inhibitors of iNOS, including inhibitors of protein synthesis and transcription factor NF-kappa B, but which (unlike murine macrophage iNOS) was not sensitive to hydrocortisone or TGF-beta. Exposure of OA-affected cartilage to interleukin 1 beta, tumor necrosis factor-alpha, and lipopolysaccharide resulted in approximately 20-50% augmentation of nitrite accumulation, which was also sensitive to cycloheximide and pyrrolidine dithiocarbamate. Hence, our data indicate that OA-NOS (based on immunoreactivity and molecular weight) is similar to ncNOS and that it releases nitric oxide, which may contribute to the inflammation and pathogenesis of cartilage destruction in OA.


Assuntos
Cartilagem/enzimologia , Neurônios/enzimologia , Óxido Nítrico Sintase/metabolismo , Osteoartrite/enzimologia , Animais , Anti-Inflamatórios/farmacologia , Bovinos , Células Cultivadas , Indução Enzimática , Humanos , Hidrocortisona/farmacologia , NF-kappa B/fisiologia , Óxido Nítrico/metabolismo , Fator de Crescimento Transformador beta/fisiologia , Regulação para Cima
19.
Orthopedics ; 18(11): 1067-71, 1995 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-8559691

RESUMO

Five types of commercial glove liners (within double latex gloves) were compared to single and double latex gloves for cut and puncture resistance and for relative manual dexterity and degree of sensibility. An apparatus was constructed to test glove-pseudofinger constructs in either a cutting or puncture mode. Cutting forces, cutting speed, and type of blade (serrated or scalpel blade) were varied and the time to cut-through measured by an electrical conductivity circuit. Penetration forces were similarly determined with a scalpel blade and a suture needle using a spring scale loading apparatus. Dexterity was measured with an object placement task among a group of orthopedic surgeons. Sensibility was assessed with Semmes-Weinstein monofilaments, two-point discrimination, and vibrametry using standard techniques and rating scales. A subjective evaluation was performed at the end of testing. Time to cut-through for the liners ranged from 2 to 30 seconds for a rapid oscillating scalpel and 4 to 40 seconds for a rapid oscillating serrated knife under minimal loads. When a 1 kg load was added, times to cut-through ranged from 0.4 to 1.0 second. In most cases, the liners were superior to double latex. On average, 100% more force was required to penetrate the liners with a scalpel and 50% more force was required to penetrate the liners with a suture needle compared to double latex. Object placement task times were not significantly liners compared to double latex gloves. Semmes-Weinstein monofilaments, two-point discrimination, and vibrametry showed no difference in sensibility among the various liners and double latex gloves. Subjects felt that the liners were minimally to moderately impairing. An acclimation period may be required for their effective use.


Assuntos
Luvas Cirúrgicas , Teste de Materiais , Doenças Profissionais/prevenção & controle , Ortopedia , Ferimentos Perfurantes/prevenção & controle , Desenho de Equipamento , Gossypium , Humanos , Látex , Ferimentos Penetrantes Produzidos por Agulha/prevenção & controle , Vibração
20.
Semin Arthroplasty ; 4(2): 117-22, 1993 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10148552

RESUMO

Revision, and complicated primary total knee arthroplasty (TKA), may present with significant structural bony defects. Allograft offers blocks of material that can be shaped to the defect. The opportunity to gain a biological bond may theoretically enhance loading conditions and enhance any subsequent surgery. However, the biomechanical and biological issues of immune response, infection, graft incorporation, resorption, and load transfer render allografting a powerful but problematic technology.


Assuntos
Transplante Ósseo/métodos , Prótese do Joelho/métodos , Adulto , Transplante Ósseo/efeitos adversos , Transplante Ósseo/instrumentação , Feminino , Humanos , Reoperação , Estresse Mecânico , Infecção da Ferida Cirúrgica/etiologia , Transplante Homólogo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...